jpeg preview

Spliced Dataset UVSUM_1X_52436



Dataset MODE-λcen Aper Range Texp MJD QF Fscl Vshft Xcorr Params
o4v652060 FITS E140M-1425 020×006 1150.0-1512.7 2000 52436.173 80 1.282 +0.82
o4v652070 FITS E140H-1598 020×009 1502.7-1687.6 1200 52436.235 99 1.000 +1.74 1510.75 [0.10]
o4v652060 FITS E140M-1425 020×006 1682.2-1699.9 2000 52436.173 80 1.218 -0.08 1684.11 [0.12]
o4v652010 FITS E230M-1978 020×005N 1614.9-2149.9 840 52436.042 90 1.218 -0.08
o4v652020 FITS E230H-2263 020×005N 2139.7-2393.2 910 52436.056 99 1.237 +0.42 2146.78 [0.22]
o4v652030 FITS E230H-2513 020×005N 2378.6-2641.3 600 52436.105 99 1.301 +0.28 2385.93 [0.28]
o4v652040 FITS E230H-2762 020×005N 2621.1-2887.7 600 52436.117 99 1.416 -0.20 2639.15 [0.20]
o4v652050 FITS E230H-3012 020×005N 2885.6-3146.0 600 52436.129 99 1.016 -2.90 2885.80 [0.20]

Notes. Aperture code: 020×009= 0.20″×0.09″. Range is in Å. Texp is total exposure time (seconds). MJD is first start date of a sequence. "QF" is quality factor. "Fscl" is flux scale factor. "Vshft" is wavelength correction (in km/s) derived from cross-correlation. The template parameters (λ and [Δλ]) are in Å. The cross-correlation, if any, was applied between the template spectrum and the preceding one. If no template params are reported, a "blind" coaddition of the overlapping wavelengths of the pair was performed.

Back to Portal