ZEROFRAM

Zero frame was downlinked separately

T if zero frame was read separately. The first frame of an integration may be read out separately, even if that frame is also averaged into the first group of the integration. If there is a zero frame readout, there will be one for each integration. The zero frame will be stored in a data array in a separate fits extension.

Attribute Value
data type boolean
enumerated Values not defined
units
example F
default value F
special processing not defined
source Science Image Header
software source
calculation If Group ID = 0 (in sci_img_hdr), then a zero frame readout is identified
DB destination ['ScienceCommon.zerofram', 'GuideStar.zerofram']
data type in DB nchar(1)
instrument Multiple
mode All
product level 1a
FITS hdu PRIMARY
FITS header section Exposure